Call for tenders' details

Title:
Framework supply contract for gamma spectroscopy equipment
Contracting authority:
European Commission, DG Energy (ENER)
TED publication date:
23/08/2018
Time limit for receipt of tenders:
18/10/2018
Status:
Closed
Information
ENER/E1/2018-13-11
Framework supply contract for gamma spectroscopy equipment
The subject matter of the framework contract is the supply of gamma spectroscopy equipment.
Supplies
Open procedure
Closed
Checked
One or more lot
Framework agreement
Conditions for participation
Selection criteria as stated in the procurement documents
Selection criteria as stated in the procurement documents
Selection criteria as stated in the procurement documents
Selection criteria as stated in the procurement documents
Milestones
23/08/2018 00:00
18/10/2018 16:00
19/10/2018 10:30
Lots
Lot number Title Description
Lot 1
Compact gamma spectrometers with high quality CdZnTe detection crystals of different sizes
The charge sensitive preamplifier, main amplifier, digital signal processor and high and low voltage power supplies shall be integrated in one housing together with the detection crystal. The spectrometer shall be powered via the USB port of a computer with which it will communicate using the Windows based GBS MCA166/MCA527 WinSPEC for inspectors software.
Lot 2
Spectrometric detection probes with high efficiency large volume CdZnTe quasi-hemispherical detectors of different sizes
The detection probes shall consist of the CdZnTe detector and a charge sensitive preamplifier mounted inside the same housing. The cable of the detection probe should be radiation-resistant and have lengths up to 20m.The cable connecting the spectrometer cable to the recording equipment should be radiation-resistant and have lengths up to 30m.
Lot 3
Spectrometric detection probes with small volume CdZnTe quasi-hemispherical detectors of different sizes
The detection probes shall consist of the CdZnTe detector and a charge sensitive preamplifier mounted inside a very compact pencil-shaped housing. The cable of the detection probe should be radiation-resistant and have lengths up to 20m.
Lot 4
High efficiency large volume CdZnTe quasi-hemispherical detectors of different sizes
High efficiency large volume CdZnTe quasi-hemispherical detectors of different sizes
Lot 5
Compact low noise, charge-sensitive preamplifiers for gamma spectroscopy with room temperature operated semi-conductor detectors
The electronic circuitry should include bias filtering and input circuit protection functionality.The cable of the preamplifier should be radiation-resistant and have lengths up to 20m.The cable connecting the preamplifier cable to the recording equipment should be radiation-resistant and have lengths up to 30m.
Notices
Reference Notice type Publication date
2018/S 188-423864
Corrigendum
29/09/2018 00:00
2018/S 175-396033
Corrigendum
12/09/2018 00:00
2018/S 161-367660
Contract notice
23/08/2018 00:00