Results per page: 10 | 25 | 50 9 Questions found, displaying all Questions .
# Question Answer Last publication date Status
9
In the Administrative Annex Appendix Costs, the unit prices for the HW come multiplied by variable factors [...]
There is no inconsistency in the table Appendix II Price evaluation scenario. The price to be introduced [...]
19/04/2016
8
Into the price evaluation scenario, the final price Po is the result of the formula : Po=Price case ID [...]
The scenario serves only the purpose of price evaluation and in no case constitutes a commitment to purchase [...]
15/04/2016
7
Should the Barometric and Wind Station (ID 8 and ID 9) have a dedicated data logger each one? Or should [...]
In general, they should be connected to the generic data acquisition devices with an integrated output [...]
14/04/2016
6
Should this system be used as an indipendent device or could it be necessary to connect it to the other [...]
It could be necessary to connect system ID 15 to the other data acquisition systems. For example an integrated [...]
12/04/2016
5
for better examination and assessment of your technical needs in order to submit a more detailed offer [...]
Please also see the published announcement.
08/04/2016
4
How many CAN ports must have? It has to be registered locally or it must be an interface of the measurement [...]
The system shall have at least two independent CAN High Speed Ports with interface to the measurement [...]
08/04/2016
3
It means a programmable convertor as per protocol CAN with an analogic signal? If yes, how may analogical [...]
Yes, it means a programmable converter from CAN protocol to analogic signal; at least two analogic output [...]
08/04/2016
2
In may be a typing error? The previous item (ID 6 Potentiometers for motorcycles type short wire) indicated [...]
The value of 3000mm is correct.
08/04/2016
1
We kindly ask to confirm us that bank guarantee is not requested.
No bank guarantee is requested
08/04/2016