17
|
Does BEREC require strict compliance to the testing methodologies outlined in the BEREC Net Neutrality [...]
|
In general, all measurement methodology shall respect international standards, recommendations and best [...]
|
03/05/2018
|
|
16
|
Does BEREC require the ability to deploy dedicated hardware for the purpose of the measurement tests, [...]
|
The hardware, internet uplink and the colocation facility has to be provided by the contractor during [...]
|
03/05/2018
|
|
15
|
Who would be responsible for maintaining the clientside applications of the reference system after the [...]
|
For the agreed maintenance period, the contractor has to manage and provide maintenance for the Reference [...]
|
03/05/2018
|
|
14
|
Could you please confirm that the delivery requested is just for a reference system? NRA will eventually [...]
|
In the scope of this tender is only the reference system. Any subsequent NRA systems are out of scope [...]
|
03/05/2018
|
|
13
|
Is hardware servers are to be delivered in the scope of this tender or sizing guidelines?
|
Hardware has to be supplied by the contractor in the scope of this tender (Req-84).
|
03/05/2018
|
|
12
|
Is an offer above the estimated budget (240k) would lead to rejection of the offer?
|
Any tender exceeding the maximum available budget of 240.000 Euro (two hundred forty thousand Euro) as [...]
|
02/05/2018
|
|
11
|
For a cartographical presentation of measurement results our solution uses Google Maps as a base layer [...]
|
In order to comply with privacy regulations, a solution has to be implemented that allows the use of [...]
|
26/04/2018
|
|
10
|
Regarding Req-51 - does this exclude out of band access to administrative tools? Or is this requirement [...]
|
The usage of out-of-band access is in line with this requirement as long as the provided security is [...]
|
26/04/2018
|
|
9
|
Regarding Req-39 - Once the user consent is withdrawn, should the test results associated to the user [...]
|
The solution has to be compliant with data protection laws, particularly with the GDPR (esp. recital [...]
|
26/04/2018
|
|
8
|
Regarding Req-27 - Can the test environment run on a low throughput network not able to give accurate [...]
|
The Reference System shall be at least capable of 10 simultaneous tests with an aggregated bandwidth [...]
|
26/04/2018
|
|