25
|
The amount of Operation Meetings has been specified for Phase 1 (WPK2 and WPK3). It is however not clear [...]
|
The Operation Meetings are not specified for Phase 2, i.e. they are not foreseen. In case they should [...]
|
20/06/2019
|
|
24
|
In document "EN-05 Annex I Part 2 Technical Specifications", chapter "2.2. Scalability requirements", [...]
|
For the purpose of Phase 2 in the evaluation table, the number of 21 is only indicative to provide an [...]
|
20/06/2019
|
|
23
|
In terms of "interacting with the Accredited Auditors" can the JRC clarify whether CA compliance audits [...]
|
We confirm that the contractor will be responsible for the entire process of auditing the EU Root CA, [...]
|
20/06/2019
|
|
22
|
a) Would you accept an offer that includes the number of 2.000.000 supported C-ITS stations per year [...]
|
Ad a) Even if your business model is not certificate based, you please still need to give an indication [...]
|
20/06/2019
|
|
21
|
Could you please indicate the maximum number of Authorisation Tickets (Certificates) in case that the [...]
|
CORRIGENDUM: INSTEAD OF 'Annex I - Part 2: Technical Specifications does not define a maximum amount [...]
|
20/06/2019
|
|
20
|
a) Could you please indicate the maximum number of Authorisation Tickets (Certificates) for the 50.000 [...]
|
CORRIGENDUM INSTEAD OF 'However, please refer also to point 1.2 Scalability Requirements within the table [...]
|
19/06/2019
|
|
19
|
Questions asked again, this time in layman's terms. Please respond accordingly. a) Can a solution be [...]
|
Ad a) Regarding the question on location of data centres, please see again the answer to Question 10. [...]
|
19/06/2019
|
|
18
|
Could we assume English as language for all relevant project communication and support issues?
|
Yes, as defined also in several parts of Annex I – Part 2: Technical Specifications, see in sections [...]
|
19/06/2019
|
|
17
|
We would like to understand the measurement of ""each day of delay"". a) We interprete a day of delay [...]
|
a) The WKP1 shall be performed within 12 (twelve) months starting from the date on which the contract [...]
|
19/06/2019
|
|
16
|
With respect to tender compliance described in Annex 1, Part 1, section 2.4, can the JRC clarify whether [...]
|
The maximum total contract value is as described in point 2.6 in the Administrative Annex. Thus, price [...]
|
19/06/2019
|
|