17
Does BEREC require strict compliance to the testing methodologies outlined in the BEREC Net Neutrality [...]
In general, all measurement methodology shall respect international standards, recommendations and best [...]
03/05/2018
16
Does BEREC require the ability to deploy dedicated hardware for the purpose of the measurement tests, [...]
The hardware, internet uplink and the colocation facility has to be provided by the contractor during [...]
03/05/2018
15
Who would be responsible for maintaining the clientside applications of the reference system after the [...]
For the agreed maintenance period, the contractor has to manage and provide maintenance for the Reference [...]
03/05/2018
14
Could you please confirm that the delivery requested is just for a reference system? NRA will eventually [...]
In the scope of this tender is only the reference system. Any subsequent NRA systems are out of scope [...]
03/05/2018
13
Is hardware servers are to be delivered in the scope of this tender or sizing guidelines?
Hardware has to be supplied by the contractor in the scope of this tender (Req-84).
03/05/2018
12
Is an offer above the estimated budget (240k) would lead to rejection of the offer?
Any tender exceeding the maximum available budget of 240.000 Euro (two hundred forty thousand Euro) as [...]
02/05/2018
11
For a cartographical presentation of measurement results our solution uses Google Maps as a base layer [...]
In order to comply with privacy regulations, a solution has to be implemented that allows the use of [...]
26/04/2018
10
Regarding Req-51 - does this exclude out of band access to administrative tools? Or is this requirement [...]
The usage of out-of-band access is in line with this requirement as long as the provided security is [...]
26/04/2018
9
Regarding Req-39 - Once the user consent is withdrawn, should the test results associated to the user [...]
The solution has to be compliant with data protection laws, particularly with the GDPR (esp. recital [...]
26/04/2018
8
Regarding Req-27 - Can the test environment run on a low throughput network not able to give accurate [...]
The Reference System shall be at least capable of 10 simultaneous tests with an aggregated bandwidth [...]