21
|
Could you please indicate the maximum number of Authorisation Tickets (Certificates) in case that the [...]
|
CORRIGENDUM: INSTEAD OF 'Annex I - Part 2: Technical Specifications does not define a maximum amount [...]
|
20/06/2019
|
|
22
|
a) Would you accept an offer that includes the number of 2.000.000 supported C-ITS stations per year [...]
|
Ad a) Even if your business model is not certificate based, you please still need to give an indication [...]
|
20/06/2019
|
|
23
|
In terms of "interacting with the Accredited Auditors" can the JRC clarify whether CA compliance audits [...]
|
We confirm that the contractor will be responsible for the entire process of auditing the EU Root CA, [...]
|
20/06/2019
|
|
24
|
In document "EN-05 Annex I Part 2 Technical Specifications", chapter "2.2. Scalability requirements", [...]
|
For the purpose of Phase 2 in the evaluation table, the number of 21 is only indicative to provide an [...]
|
20/06/2019
|
|
25
|
The amount of Operation Meetings has been specified for Phase 1 (WPK2 and WPK3). It is however not clear [...]
|
The Operation Meetings are not specified for Phase 2, i.e. they are not foreseen. In case they should [...]
|
20/06/2019
|
|
26
|
The number of Authorisation Tickets (Certificates) is an important value for the performance requirement [...]
|
We cannot confirm nor correct your calculation. The rules to define the number of authorization tickets [...]
|
20/06/2019
|
|
27
|
Could you please provide the percentage breakdown of fixed and mobile C-ITS stations?
|
The percentage breakdown is not defined at this moment as it will depend on the market demand. It is [...]
|
20/06/2019
|
|
28
|
Can we assume to use a link certificate and a self signed certificate to prove the possession of the [...]
|
As stated in 3.2.1 of [1], the root CA shall prove that it rightfully holds the private key corresponding [...]
|
20/06/2019
|
|
29
|
Could you please provide the number of 'of end-entities’ subscriber organisations?
|
This is not defined at this moment as it is based on market demand. It is foreseen that the Specific [...]
|
20/06/2019
|
|
30
|
Could you please provide the number of C-ITS station types?
|
This is not defined at this moment as it is based on market supply of C-ITS stations.
|
20/06/2019
|
|