12
You mentioned some LOQ for heavy metals that are exceptionally low for some compounds. Are they mandatory [...]
For the indicated substances, we can accept LOQ in the following ranges: Mercury: 0.00005 - 0.025 mg/ [...]
22/06/2018
Freagartha
9
What is expected time from opening offers, when contract will be signed and project started?
After the opening of offers, the evaluation process will take place. This full process up to contract [...]
22/06/2018
Freagartha
8
We kindly ask you to provide a full set of Tender documentation in French for the whole 3 lots. Is to [...]
The French tender documents are online from today, 20 June 2018.
20/06/2018
Freagartha
7
We kindly ask you to inform us about the LOQ for LOT1 especially for heavy metalls but also for basic [...]
Please find here after the limit of quantification (LOQ) in mg/kg for each heavy metal: As 2.84 Cd 0.07 [...]
22/06/2018
Freagartha
20
Since the proposed requirements for quantification of antibiotic resistance genes are extremely specific [...]
As indicated in the Technical Specifications, the use of alternative methods would be acceptable provided [...]
22/06/2018
Freagartha
5
SIAMO INTERESSATI AL LOTTO 1 E LOTTO 3
Da oggi 7 giungo 2018 la documentazione di gara è disponibile anche in italiano.
07/06/2018
Freagartha
11
Regarding Criterion T1:The tenderer must prove experience in the field of analysing plant protection [...]
The tenderer has to prove analysis of each group of PPPs and antibiotics in Table 2 of the Technical [...]
22/06/2018
Freagartha
15
On the 6th page there is the sentence: "For brand names indicated in the Technical Specifications, fully [...]
Brands refer to trademarks, standards or producers names.
22/06/2018
Freagartha
1
NELLA LIBRERIA DI DOCUMENTI E' PRESENTE LA DOCUMENTAZIONE SOLO IN LINGUA INGLESE SI RICHIEDE SE POSSIBILE [...]
Sì, è possibile. Potete indicarci a che lotto siete interessati?
01/06/2018
Freagartha
10
Lot 1 - Heavy metals specifies that the solutions resulting form aqua regia digestion should be analysed [...]
As indicated in the Technical Specifications, the use of an ICP-MS would be acceptable provided that [...]
22/06/2018
Freagartha