35
|
Considering the Christmas and end year period and in order to secure quality and competitive proposals [...]
|
Please be informed that we have already added an extra two weeks for this Christmas Holidays
|
20/12/2021
|
|
34
|
We would like to declare as supporting entities, only entities we are relying on for their technical [...]
|
When “supporting entities” are subcontractors on which you rely upon to fulfil the selection criteria [...]
|
20/12/2021
|
|
33
|
Under Criterion A5 we read that the tenderer must prove that it has a valid ISO 27001 certificate or [...]
|
(see Q&A 31) The Consortium shall have a valid ISO 27001 certificate or equivalent, or all members [...]
|
20/12/2021
|
|
32
|
On page 36. of Tender specifications, under Criterion A3, you request that “The tenderer must prove experience [...]
|
The understanding is correct. The projects to prove experience working in English are not necessarily [...]
|
15/12/2021
|
|
31
|
The introduction to Criteria A reads "Tenderers (in case of a joint tender the combined capacity of all [...]
|
Q&A 19 is aligned with the tender specifications. If only one member of the Consortium has a valid [...]
|
14/12/2021
|
|
30
|
We note that the client statements in connection with the project references are not listed in the list [...]
|
No these documents must be provided with the tender to prove they fulfil the technical and professional [...]
|
14/12/2021
|
|
29
|
In Declaration on Honour, section “Selection criteria applicable individually to the involved entities [...]
|
Your understanding is correct, (b) and (c) is N/A for joint tenders.
|
14/12/2021
|
|
28
|
The section "B - Selection Criteria" in the Declaration on Honour as it can be found in the Technical [...]
|
Please use the version in Technical specifications. We will upload a new Word version shortly.
|
14/12/2021
|
|
27
|
On page 35. of Tender specifications, under Criterion A1, you request that the software under each project [...]
|
Criterion A1 is requesting to "prove experience in developing software with at least two projects delivered [...]
|
13/12/2021
|
|
26
|
With reference to 3.2.3. Technical and professional capacity under Criterion A1 it is stated that ‘The [...]
|
The interpretation is correct. The 5.000 person-days refers to the total volume of the project, delivered [...]
|