9
|
What is expected time from opening offers, when contract will be signed and project started?
|
After the opening of offers, the evaluation process will take place. This full process up to contract [...]
|
22/06/2018
|
|
10
|
Lot 1 - Heavy metals specifies that the solutions resulting form aqua regia digestion should be analysed [...]
|
As indicated in the Technical Specifications, the use of an ICP-MS would be acceptable provided that [...]
|
22/06/2018
|
|
11
|
Regarding Criterion T1:The tenderer must prove experience in the field of analysing plant protection [...]
|
The tenderer has to prove analysis of each group of PPPs and antibiotics in Table 2 of the Technical [...]
|
22/06/2018
|
|
12
|
You mentioned some LOQ for heavy metals that are exceptionally low for some compounds. Are they mandatory [...]
|
For the indicated substances, we can accept LOQ in the following ranges: Mercury: 0.00005 - 0.025 mg/ [...]
|
22/06/2018
|
|
13
|
In respect of the 24-month guarantee period applying to Lots 2 and 3; can the customer confirm its expectation [...]
|
A guarantee of two years is required on the accuracy of information if seemingly anomalous values become [...]
|
22/06/2018
|
|
14
|
How compliance with the applicable environmental, social and labour law obligations established by Union [...]
|
At this stage tenderers do not need to prove this compliance in their offer. The Contracting Authority [...]
|
22/06/2018
|
|
15
|
On the 6th page there is the sentence: "For brand names indicated in the Technical Specifications, fully [...]
|
Brands refer to trademarks, standards or producers names.
|
22/06/2018
|
|
20
|
Since the proposed requirements for quantification of antibiotic resistance genes are extremely specific [...]
|
As indicated in the Technical Specifications, the use of alternative methods would be acceptable provided [...]
|
22/06/2018
|
|
18
|
Can tender participants offer improved primers to sequence fungal ITS1 and ITS2 region or are the requested [...]
|
The use of an alternative high-throughput sequencing platform is not allowed. Tenderer shall use a single [...]
|
22/06/2018
|
|
19
|
In the tender, ligation of Illumina indexes is requested for each PCR-amplified sample separately. Do [...]
|
As indicated in the Technical Specifications, the use of alternative methods would be acceptable provided [...]
|
22/06/2018
|
|