7
|
Why does the tender only put emphasis on the encryption of classified data exchanges between EDA and [...]
|
As said in the general statement (see reply to question 4), the implementation of filtering and data [...]
|
19/08/2019
|
|
4
|
Why does the tender not include the term or any reference to cross domain solutions (CDS) which are an [...]
|
General statement: The elements quoted in the call for tender are here to guide tenderers and help them [...]
|
19/08/2019
|
|
5
|
Why are the following solutions/technologies not in scope for the tender: a. Data diode (unidirectional [...]
|
a. As said in the general statement (Q4), the implementation of data diode can be part of the future [...]
|
19/08/2019
|
|
11
|
What type of transfer protocols does EDA intend to use to shared data between the classified system and [...]
|
The technical solution for any interconnection will be defined in a later stage as part of the system [...]
|
19/08/2019
|
|
10
|
What type of data formats will be shared between EDA classified systems and the systems it intends to [...]
|
The full scope of this interconnection will be defined in a later stage as part of the system design.
|
19/08/2019
|
|
21
|
Uplifts/discounts should be offered in relation to the price list of the respective manufacturer. Not [...]
|
The uplift is a margin that the selected contractor will be allowed to apply to any purchases made within [...]
|
25/09/2019
|
|
13
|
To ensure fair comparability, can EDA provide a form that lists all elements of supply chain security [...]
|
The description of the security of supply chain is subject to competition and EDA does not have any specific [...]
|
19/08/2019
|
|
24
|
The formulas in cells G30 to G33 are incorrect. For a correct result, the part [/100] at the end of each [...]
|
Please refer to the updated financial table – “Financial proposal template 25.09.2019” (corrigendum number [...]
|
25/09/2019
|
|
23
|
The formula in cell D24 is incorrect. For a correct result, it must be [=D23*(1+D22)]. We ask for appropriate [...]
|
Please refer to the updated financial table – “Financial proposal template 25.09.2019” (corrigendum number [...]
|
25/09/2019
|
|
17
|
In the requirements for Scenario A EDA requests the costs for a minimum set of hardware items. These [...]
|
1. No, the solution proposed for Scenario A must include a HSM. 2. This is not a requirement. Tenderers [...]
|
22/08/2019
|
|