57
"Technical specifications describe that ‘‘Pulsation: 0.1 MPa" The technical specification refers to a [...]
Based on the market research carried out for the preparation of the technical specifications, this item [...]
17/08/2021
Udzielona odpowiedź
15
- It has been requested in the Tech Spec – “The motor fan should be double suction and 2650 m3/h.”, although [...]
According to PRAG, section 4.3.4 - Additional information during the procedure - “No prior opinion on [...]
05/08/2021
Udzielona odpowiedź
48
1) Item 13 Autoclave. Can you please confirm chamber volume? 420 litres is very big and the max chamber [...]
1) Based on the market research carried out for the preparation of the technical specifications, this [...]
17/08/2021
Udzielona odpowiedź
16
1. It has been requested illumination minimum 12 W-30 V. Will you agree to accept illumination 3W LED [...]
According to PRAG, section 4.3.4 - Additional information during the procedure - “No prior opinion on [...]
05/08/2021
Udzielona odpowiedź
44
Dear Sirs Reference is made to project "REFORM/2021/EA-OP/0005 “ We bring to your attention the fact [...]
See our replies to questions 28, 29, 30 and 31.
17/08/2021
Udzielona odpowiedź
3
Dear Sirs, please inform us about the final site(s) of delivery for the equipment, is the final delivery [...]
As described in the Instructions to tenderers point 1.1: “1.1. The subject of the contract is the supply [...]
23/07/2021
Udzielona odpowiedź
4
Dear Sirs, We are unable to open the drawings pdf document. The document seems to be corrupted. Could [...]
Please, try now
23/07/2021
Udzielona odpowiedź
45
In particular: Item 2 - ICP-OES (Inductively coupled plasma - optical emission spectroscopy) system The [...]
Based on the market research carried out for the preparation of the technical specifications, this item [...]
17/08/2021
Udzielona odpowiedź
12
It has been requested the scope of supply to include: Fume cupboard must have four glass manifolds. Glass [...]
According to PRAG, section 4.3.4 - Additional information during the procedure - “No prior opinion on [...]
05/08/2021
Udzielona odpowiedź
6
It has been requested – “support stand with levelling screws adjustable from 55- 85 mm.” Will you agree [...]
According to PRAG, section 4.3.4 - Additional information during the procedure - “No prior opinion on [...]
05/08/2021
Udzielona odpowiedź