Call for tenders' details

Title:
Laboratory analyses of topsoil samples collected in the context of the LUCAS 201...
Contracting authority:
European Commission, Joint Research Centre (JRC)
TED publication date:
31/05/2018
Time limit for receipt of tenders:
02/07/2018
Status:
Closed
Show filter parameters

Results per page: 10 | 25 | 50 24 Questions found, displaying 11 to 20.[First/Prev] 1, 2, 3 [Next/Last]
# Question Answer Last publication date Status
9
What is expected time from opening offers, when contract will be signed and project started?
After the opening of offers, the evaluation process will take place. This full process up to contract [...]
22/06/2018
10
Lot 1 - Heavy metals specifies that the solutions resulting form aqua regia digestion should be analysed [...]
As indicated in the Technical Specifications, the use of an ICP-MS would be acceptable provided that [...]
22/06/2018
11
Regarding Criterion T1:The tenderer must prove experience in the field of analysing plant protection [...]
The tenderer has to prove analysis of each group of PPPs and antibiotics in Table 2 of the Technical [...]
22/06/2018
12
You mentioned some LOQ for heavy metals that are exceptionally low for some compounds. Are they mandatory [...]
For the indicated substances, we can accept LOQ in the following ranges: Mercury: 0.00005 - 0.025 mg/ [...]
22/06/2018
13
In respect of the 24-month guarantee period applying to Lots 2 and 3; can the customer confirm its expectation [...]
A guarantee of two years is required on the accuracy of information if seemingly anomalous values become [...]
22/06/2018
14
How compliance with the applicable environmental, social and labour law obligations established by Union [...]
At this stage tenderers do not need to prove this compliance in their offer. The Contracting Authority [...]
22/06/2018
15
On the 6th page there is the sentence: "For brand names indicated in the Technical Specifications, fully [...]
Brands refer to trademarks, standards or producers names.
22/06/2018
20
Since the proposed requirements for quantification of antibiotic resistance genes are extremely specific [...]
As indicated in the Technical Specifications, the use of alternative methods would be acceptable provided [...]
22/06/2018
18
Can tender participants offer improved primers to sequence fungal ITS1 and ITS2 region or are the requested [...]
The use of an alternative high-throughput sequencing platform is not allowed. Tenderer shall use a single [...]
22/06/2018
19
In the tender, ligation of Illumina indexes is requested for each PCR-amplified sample separately. Do [...]
As indicated in the Technical Specifications, the use of alternative methods would be acceptable provided [...]
22/06/2018